Pacemaker implantation is a procedure used to place a small device that helps maintain an appropriate heart rate when the heart's natural electrical system is not working reliably. The procedure is commonly performed for conditions such as symptomatic bradycardia, certain types of heart block, and other electrical conduction problems.
For most patients, traditional pacemaker implantation involves placing a pulse generator beneath the skin of the upper chest and guiding one or more thin leads through a vein into the heart. Leadless pacemakers use a different approach: the self-contained device is delivered through a blood vessel and positioned directly inside the heart.
The exact technique depends on the type of pacemaker being used and the patient's specific heart rhythm problem. You can learn more about the overall treatment in this guide to pacemaker implantation.
What Happens Before Pacemaker Implantation?
Before the procedure, the cardiology team confirms that a pacemaker is appropriate and determines which type of device best matches the patient's needs. The evaluation may include:
- Medical history and physical examination
- Electrocardiogram (ECG)
- Heart rhythm monitoring
- Echocardiography or other cardiac imaging when needed
- Blood tests
- Review of current medicines
- Assessment of the patient's overall health and suitability for the procedure

*AI-generated image - for illustration only. Clinical accuracy is not guaranteed.
How Is a Traditional Pacemaker Implanted?
Traditional pacemaker implantation generally involves two main components: a pulse generator and one or more leads. The generator contains the battery and electronic circuitry, while the leads carry electrical signals between the generator and the heart.
1. Anaesthesia is given
The procedure is usually performed using local anaesthesia to numb the area where the device will be placed. Sedation may also be given to help the patient remain comfortable and relaxed.
The patient is generally awake or lightly sedated rather than receiving full general anaesthesia, although the approach can vary depending on the patient's condition and the clinical circumstances.
2. A small incision is made
The doctor makes a small incision, usually in the upper chest below the collarbone. A space beneath the skin is created to accommodate the pacemaker generator. This space is commonly called the pacemaker pocket.
3. The leads are guided into the heart
One or more thin pacemaker leads are introduced through a vein and carefully guided toward the heart using imaging guidance. The number and position of the leads depend on the patient's rhythm problem and the type of pacemaker required.
For example, a single-chamber system may use one lead, while a traditional dual-chamber system generally has one lead positioned in the right atrium and another in the right ventricle.
4. The leads are positioned and tested
Once the leads reach the appropriate location, the doctor checks their position and electrical performance. The leads must be able to reliably sense the heart's electrical activity and deliver pacing impulses when needed.
The team may make adjustments to ensure that the system is functioning appropriately before completing the implantation.
5. The leads are connected to the generator
After the leads are positioned correctly, they are connected to the pacemaker generator. The generator is then placed inside the pocket beneath the skin.
6. The incision is closed
The incision is closed using appropriate sutures or another closure method. A dressing is placed over the area, and the patient is monitored after the procedure.
How Is a Leadless Pacemaker Implanted?
Leadless pacemakers are implanted differently because they do not have a chest generator or conventional leads.
The procedure generally involves:
- A catheter is inserted through a large blood vessel, commonly through a vein in the groin.
- The catheter is guided through the blood vessels toward the heart.
- The leadless pacemaker is delivered through the catheter.
- The device is positioned inside the appropriate heart chamber.
- The device is secured and tested to confirm appropriate electrical performance.
- The delivery catheter is removed.
Because the device is placed directly inside the heart, a leadless pacemaker does not require a surgical pocket beneath the skin of the chest.

*AI-generated image - for illustration only. Clinical accuracy is not guaranteed.
How Many Leads Are Needed?
The number of leads depends on the type of pacemaker and the patient's electrical conduction problem.
Single-chamber pacemaker
A single-chamber traditional pacemaker generally uses one lead, most commonly positioned in the right ventricle.
Dual-chamber pacemaker
A dual-chamber traditional pacemaker generally uses two leads, one in the right atrium and one in the right ventricle. This allows the device to sense and coordinate activity between these chambers.
Leadless pacemaker
A conventional leadless pacemaker is a self-contained device and does not use traditional leads. Newer leadless technologies have expanded pacing capabilities, so the exact approach depends on the specific device and the patient's requirements.
How Long Does Pacemaker Implantation Take?
The duration of pacemaker implantation varies according to the type of device, the number of leads being placed, the patient's anatomy, and whether there are any technical difficulties during the procedure.
A straightforward traditional pacemaker procedure may take around one to two hours, although some procedures can take longer. Leadless pacemaker implantation also varies in duration.
Is Pacemaker Implantation Painful?
Local anaesthesia is used to numb the implantation area, so significant pain during the procedure is generally avoided. Some patients may feel pressure, movement, or mild discomfort while the leads are being positioned.
After the procedure, soreness, tenderness, or bruising around the incision can occur. These symptoms usually improve as the area heals.
How Is the Pacemaker Programmed?
Once the device has been implanted, it is programmed according to the patient's heart rhythm and pacing needs. A programmer placed outside the body communicates wirelessly with the pacemaker.
The medical team can review information from the device and adjust settings without another operation. The settings may be adjusted during follow-up appointments as the patient's condition and pacing requirements change.
What If the Pacemaker Is Not Working Properly?
Modern pacemakers are designed to continuously monitor the heart's electrical activity and provide pacing when required. The device is also checked during follow-up visits to identify problems with battery status, leads, or other functions.
If a traditional pacemaker lead develops a problem, additional evaluation may be required and, in some cases, the lead may need to be repositioned or replaced.
Leadless systems do not have conventional leads, so they do not develop traditional lead-related complications. However, they require their own device-specific follow-up and management.
The Bottom Line
Pacemaker implantation involves placing a device that supports the heart when its natural electrical system cannot maintain an adequate rhythm. With a traditional pacemaker, a generator is placed beneath the skin of the chest and connected to the heart through one or more leads. A leadless pacemaker is delivered through a blood vessel and positioned directly inside the heart.
The procedure is carefully planned around the patient's rhythm disorder and pacing requirements. After implantation, the device is tested and programmed, and regular follow-up helps ensure that it continues to function appropriately.

*AI-generated image - for illustration only. Clinical accuracy is not guaranteed.
Although pacemaker implantation is generally a well-established procedure, the technique, recovery period, and follow-up plan can vary from one patient to another. Your cardiology team can explain the specific approach recommended for your condition.